All tenders
Awarded
  • Supply

AMB/2026/02 - Fornitura e posa Cogeneratore - IDA Giubiasco

Published in Italian. Sign in and TEXFY shows the texts in English. Sign in

Location
Canton TI
Procuring office
Azienda Multiservizi Bellinzona (AMB)
Go to the official tender(simap.ch, opens in a new tab)

Awarded

According to the simap publication. Values that are not given are deliberately missing here.

Awarded to

As published on simap.ch: winner and price (with or without VAT, as stated).

  • Award of 13.04.20261 bid

    • IWK Integrierte Wärme und Kraft AG, SeuzachPrice not published
Awards of this contracting authority

The price is not published under public procurement law.

What is being procured?

Scope of work

Oggetto dell'appalto è

Smontaggio e smaltimento di:

  • cogeneratore esistente, quadro comando e potenza, inclusi scollegamenti elettrici tra i due
  • condotte sotto la botola di manutenzione

Fornitura e posa di:

  • cogeneratore per biogas prodotto da digestione anaerobica con potenza 250 kWel, completa di tutti i relativi accessori
  • cabina insonorizzazione, sistema dell’olio
  • quadro di comando e quadro di potenza, incluso allaccio tra BHKW e quadri.
  • sistema rilevazione gas e incendi
  • catalizzatore per rispetto limite di emissione
  • scambiatore di calore dei fumi per recupero termico, inclusi accessori
  • silenziatore gas di scarico (esterno al modulo, solo fornitura);
  • circuito raffreddamento emergenza con scambiatore calore a fascio tubiero
  • circuito raffreddamento miscela con scambiatore calore a fascio tubiero
  • condotta di immissione biogas nel BHKW e rampa gas, e valvola rompifiamma
  • condotte circuito di riscaldamento, raffreddamento emergenza (fino a scambiatore), raffreddamneto miscela (fino a scambiatore)
  • solo fornitura ventilatore di aspirazione aria
  • solo fornitura silenziatori per circuito di ventilazione.

OPZIONE: contratto di manutenzione “full service”, incluso di tutti gli interventi di manutenzione ordinaria e straordinaria per il periodo di funzionamento previsto (60'000 ore di esercizio).

Costituisce inoltre parte integrante del presente appalto tutto quanto occorre per l’avviamento, l’esercizio in prova ed in garanzia, e la consegna ad AMB in perfetto stato di funzionamento di tutto quanto verrà fornito. Le installazioni devono essere conformi alle attuali normative e linee guida in termini di sicurezza sul lavoro e tutela della salute, come ad esempio SUVA.

Key facts, codes and options

Type of contract
Supply
Type of supply
Purchase
Procedure
Open procedure
Trades
Not evident from the available publication data.
CPV
  • CPV 45251220 – Cogeneration plant construction work
  • CPV 31100000 – Electric motors, generators and transformers
  • CPV 42100000 – Machinery for the production and use of mechanical power
  • CPV 42941000 – Machinery for the heat treatment of gas
Options
Not evident from the available publication data.
Variants
Not evident from the available publication data.
Partial offers
Not evident from the available publication data.

TEXFY assessment: Products, installations, quantities, technical specifications and exclusions are not structured fields of the publication. TEXFY does not analyse the free text on them: check the original text and the tender documents.

Official source

Go to the official tender(simap.ch, opens in a new tab)
simap project number
31066
Publication number
31066-02
Covered by international agreements
No

Checked against simap: 11.11.2026, 08:08

Export

This is not an official publication. Only the data published on the platform www.simap.ch is authoritative. Dies ist keine amtliche Veröffentlichung. Massgebend sind die auf der Plattform www.simap.ch veröffentlichten Daten. Anyone who reuses this data complies with the conditions of simap.ch: terms, section 6.

Contract awards in Ticino: monthly reports
Report a data error

Is something on this page wrong, missing or badly translated? We check every report. We correct our own classification and translations ourselves; what simap publishes can only be changed by the contracting authority.

Kind of error

Please do not write personal data into it. If you are signed in, we store the report with your account.