Bio Atomic force microscope, BioAFM
• A 3 axes (XYZ) tip-scanning closed-loop atomic force microscope (AFM), providing min. 100
μm * 100 μm * (15 + 1.5) μm scan range (see Pos. 1)
• Capability to perform high speed and accuracy FD-mapping based experiments using a
small range piezo (1.5 μm) while correcting for sample tilt during the experiments using a
secondary larger range piezo (15 μm)
• Fast scanning with scan rates of up to 400 lines/sec.
• Low noise laser deflection system with 850 nm wavelength laser
• Fully automatic alignment of the laser detection system to the cantilever and
photodetector
• Fully automatic cantilever calibration regarding sensitivity and spring constant by the
thermal noise method (up to 4 MHz) or Sader method.
• Automatic, motorized 3-axes tip to surface approach up to 18 mm. Sample tilt can be
automatically corrected with the 3-axes.
• Comprehensive force-distance curve-based spectroscopy and non-resonant imaging
functionality (nrFD) to capture nano-mechanical sample properties (see Pos. 4).
• Low-noise digital high-performance AFM controller based on FPGA/PPC technology
suitable for operation in all modes.
• Data acquisition rate of force distance curves up to 1 MPixel/sec (see Pos.2).
• Sample heater for 35 mm Petri dishes and samples up to 10 mm height. With temperature
range between RT and up to 60C֯.
• Standard glass block cantilever for ease of cleaning and autoclaving.
• Capability to perform Micro-rheology on single cells or tissue samples.
Key facts, codes and options
Key facts, codes and options
- Type of contract
- Supply
- Type of supply
- Purchase
- Trades
- Not evident from the available publication data.
- CPV
- CPV 38400000 – Instruments for checking physical characteristics
- Options
- Not evident from the available publication data.
- Variants
- Not evident from the available publication data.
- Partial offers
- Not evident from the available publication data.
TEXFY assessment: Products, installations, quantities, technical specifications and exclusions are not structured fields of the publication. TEXFY does not analyse the free text on them: check the original text and the tender documents.
Official source
- simap project number
- 2372
- Publication number
- 2372-01
- Covered by international agreements
- Yes
More in the guide
Report a data error
Is something on this page wrong, missing or badly translated? We check every report. We correct our own classification and translations ourselves; what simap publishes can only be changed by the contracting authority.